| argument = subcommand.add_argument('--size-range', help='NVMe SSD device size range separated by -, can be X(m,g,t) or bytes as integer, example: --size-range 50G-1T or --size-range 1232345-67823987, --device-model and --size-range must be set together.', type=str, default='', dest='size_range', required=False) | ||
| argument = subcommand.add_argument('--nvme-names', help='Comma separated list of nvme namespace names like nvme0n1,nvme1n1.', type=str, default='', dest='nvme_names', required=False) | ||
| argument = subcommand.add_argument('--force', help='Force format detected or passed nvme pci address to 4K and clean partitions.', dest='force', action='store_true') | ||
| argument = subcommand.add_argument('--enable-inline-checksum', help='When formatting (with --force), prefer an LBAF that supports >=8 bytes of NVMe metadata per block, so alceml can run inline checksum validation in md-on-device mode. Drives with no md-capable LBAF still format to plain 4K and will use the fallback layout.', dest='inline_checksum', action='store_true') |
| if self.developer_mode: | ||
| argument = subcommand.add_argument('--disable-monitoring', help='Disable monitoring stack, false by default. Default: `false`.', dest='disable_monitoring', action='store_true') | ||
| argument = subcommand.add_argument('--strict-node-anti-affinity', help='Enable strict node anti affinity for storage nodes. Never more than one chunk is placed on a node. This requires a minimum of _data-chunks-in-stripe + parity-chunks-in-stripe + 1_ nodes in the cluster.', dest='strict_node_anti_affinity', action='store_true') | ||
| argument = subcommand.add_argument('--enable-inline-checksum', help='Enable inline CRC checksum validation on every IO for silent-data-error protection. Cannot be enabled or disabled after cluster creation. Per-device alceml mode (md-on-device vs fallback) is auto-detected at add-node.', dest='inline_checksum', action='store_true') |
| if self.developer_mode: | ||
| argument = subcommand.add_argument('--inflight-io-threshold', help='The number of inflight IOs allowed before the IO queuing starts. Default: `4`.', type=int, default=4, dest='inflight_io_threshold') | ||
| argument = subcommand.add_argument('--strict-node-anti-affinity', help='Enable strict node anti affinity for storage nodes. Never more than one chunk is placed on a node. This requires a minimum of _data-chunks-in-stripe + parity-chunks-in-stripe + 1_ nodes in the cluster."', dest='strict_node_anti_affinity', action='store_true') | ||
| argument = subcommand.add_argument('--enable-inline-checksum', help='Enable inline CRC checksum validation on every IO for silent-data-error protection. Cannot be enabled or disabled after cluster creation.', dest='inline_checksum', action='store_true') |
f7823d3 to
9273148
Compare
| for attempt in range(1, 16): | ||
| try: | ||
| client = paramiko.SSHClient() | ||
| client.set_missing_host_key_policy(paramiko.AutoAddPolicy()) |
Comment on lines
+452
to
+453
| "containers=$(docker ps -aq); " | ||
| "if [ -n \"$containers\" ]; then docker rm -f $containers; fi", |
4e3d8a4 to
ca9fa2f
Compare
| for host in self.node_hosts.values(): | ||
| try: | ||
| host.close() | ||
| except Exception: |
9ba3cbc to
9bdcc9f
Compare
Adds the sbcli control-plane support for the inline silent-data-error protection feature whose data-plane work landed on ultra branch checksum-validation. Frozen at cluster-create time; no upgrade path for existing clusters. Per-device alceml mode (md-on-device vs fallback) is auto-detected from the bound SPDK bdev's md_size at add-node and on restart, so a cluster can have a heterogeneous mix of drives. Cluster + per-device flags - Cluster.inline_checksum (bool, default False): persisted only via create_cluster / add_cluster; no mutator. - NVMeDevice.md_size (int) and NVMeDevice.md_supported (bool): set in addNvmeDevices from bdev_get_bdevs' top-level md_size field (spdk_bdev_get_md_size; emitted by lib/bdev/bdev_rpc.c). Refreshed on every restart-device path so a between-restart `nvme format` is reflected. alceml RPC plumbing (matches checksum-validation branch) - bdev_alceml_create gains optional checksum_method (1=md-on-device, 2=fallback, default 0=off), cache_size, cache_eviction_threshold; zero-defaults are not sent so the data plane keeps its built-ins (cv_default_cache_size=2000, threshold 90%). - utils.alceml_checksum_params(cluster, dev) picks 0/1/2 from the cluster flag plus md_supported. Data plane refuses method=1 on md_size==0, so the per-device decision is mandatory. - Both alceml call sites (storage_node_ops._create_storage_device_stack and device_controller restart-device) thread the params through and warn when a device falls back. CLI - cluster create / cluster add / sn configure each gain --enable-inline-checksum. - sn configure runs `find_md_lbaf_id` against `nvme id-ns` JSON to pick the smallest qualifying LBAF (ds=12, ms>=8) and forces a reformat past the existing 4K-already-formatted early-out (SectorSize stays 4096 across an md/no-md transition). Capacity accounting - alceml_fallback_overhead_bytes(cluster, size): 6 lost data blocks per 2 MiB extent (510 -> 504, ~1.171875%) when the device runs in cv_fallback_method. - lvol_controller charges that as initial provisioned utilization rather than reducing reported raw cluster_size_total, so the overhead surfaces through the existing prov_cap_warn / prov_cap_crit thresholds and md-on-device drives contribute zero. Tests - 27 new unit tests in tests/test_inline_checksum.py: model defaults, find_md_lbaf_id corner cases, alceml_checksum_params combos, fallback-overhead math (including 6/512 ratio sanity), RPC param wire-up for each method, and addNvmeDevices md detection from a mocked bdev_get_bdevs payload. Behaviour notes - Default-off cluster flag means no behaviour change for existing clusters; full unit-test suite (870 passing) stayed green during development on a separate worktree. - Data plane reads md_size itself via spdk_bdev_get_md_size, so the control plane never has to pass it. Cv_md_method does not auto fall back: control plane must pick correctly per-device, hence the add-node-time detection plumbing. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
The inline-checksum-validation control-plane work requires the matching CRC support in the data plane. Retag SIMPLY_BLOCK_SPDK_ULTRA_IMAGE from :main-latest to :checksum-validation-latest so deployed storage nodes pull the corresponding ultra build. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
… summary
Three changes that turn the lab setup script into a proper checksum-aware
deploy on the inline-checksum-validation branch.
1. Pre-deploy cleanup (Phase 1.5) on every node:
- sbctl sn deploy-cleaner (mgmt + storage; check=False so the no-op on
mgmt doesn't fail the run)
- docker rm -f stragglers + docker system prune -af --volumes
(safe BEFORE cluster create; never run after activate)
- fresh `docker pull` of SIMPLY_BLOCK_DOCKER_IMAGE and
SIMPLY_BLOCK_SPDK_ULTRA_IMAGE, image names read from the just-
installed simplyblock_core/env_var so the pulls track whatever
branch is being deployed.
2. Inline checksum enabled by default. cluster create gets
--enable-inline-checksum (frozen at create time) and sn configure
gets --enable-inline-checksum --force, so the configure step actually
takes the reformat path that picks an md-capable LBAF (ds=12, ms>=8)
instead of short-circuiting on already-4K. --no-inline-checksum
opts back out for non-checksum runs.
3. End-of-setup ALCEML mode summary. Reads each NVMeDevice's
md_size / md_supported via DBController and prints, per node and
device, whether alceml is running method=1 (md-on-device) or
method=2 (fallback / emulation), with totals. Mirrors
simplyblock_core.utils.alceml_checksum_params so the report matches
the actual data-plane configuration.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Lab counterpart of aws_dual_node_outage_soak_mixed_churn.py, designed
to run from the simplyblock jump host against the bare-metal cluster
deployed by setup_lab_perf_test1.py.
Changes vs. the AWS variant (everything else - scenario enumeration,
churn loop, fio fault detection, NIC chaos - is unchanged):
- SSH auth uses a single shared root password (--password,
SBCLI_ROOT_PASSWORD env var, or interactive prompt) instead of an
EC2 keypair. paramiko gets it via password=; the subprocess fallback
uses sshpass -e + SSHPASS env so the password never hits a command
line. paramiko is preferred (persistent connections); sshpass works
but reconnects per command.
- Default --metadata is cluster_metadata_base.json (what the lab
setup writes), default --expected-node-count is 4.
- mount_root uses /root for the root user (the AWS form
/home/{user}/... breaks because root's home is /root).
- _get_data_nics also honors metadata["data_iface"] so the single-NIC
lab metadata format works without forcing the hardcoded eth1
fallback.
- Removed Windows/EC2 key-path resolution helpers (candidate_key_paths,
resolve_key_path, --ssh-key flag).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Two adjustments for the lab cluster: - MAX_LVOL default drops from 100 to 25. The lab nodes have less capacity headroom than the AWS i3en class; 25 lvols/node is the intended ceiling for this hardware. Override via --max-lvol if needed. - New Phase 1.5d on storage nodes only: explicit per-NVMe wipe before sn configure runs. findmnt identifies the root device and skips it; every other NVMe disk gets `wipefs -af` (partition + signature cleanup) and `nvme format -f -s 0` (namespace reset). check=False so a drive that refuses format -- still held by something, RO, etc. -- logs a warning instead of aborting the deploy; sn configure --enable-inline-checksum --force will then surface the real problem and apply the md-capable LBAF on top of the clean state. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Phase 1.5c hit "dial tcp [v6]:443: cannot assign requested address" on a single storage node mid-pull, aborting the whole deploy. public.ecr.aws fronted by S3 occasionally returns those - IPv6 source race, signed-URL hiccup, etc. - and one blip on one node should not take the run down with it. Retry each docker pull up to 6 times with 15s backoff (90s of headroom). Persistent failures still error out so a real registry outage or auth problem is not silently masked. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
sbctl sn configure --force always prompts "Type YES/Y to continue" before reformatting NVMes (interactive safety in simplyblock_core/utils/__init__.py around line 1789). In an automated SSH session there's no TTY answering it, so the prompt sat for the full 600s subprocess timeout and the deploy aborted on every storage node: WARNING: Formating Nvme devices /dev/nvme1n1 /dev/nvme0n1 Type YES/Y to continue: ... TimeoutExpired after 600 seconds Wrap the configure invocation with `echo YES | ...` only when inline checksum mode is on (the path that actually adds --force). Localized to the one command so we don't have to plumb stdin through ssh_exec for everything. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
When the two NVMes on a node format to different LBAFs (e.g. one drive exposes an md-capable LBAF and the other doesn't, so find_md_lbaf_id returns md=8 for one partition and md=0 for the other), SPDK's RAID1 layer rejects the JM mirror with -EINVAL: bdev_raid.c:3567 *ERROR*: Raid bdev 'raid_jm_<uuid>' has different metadata format than base bdev 'nvme_<...>n1p1' That prevents sn add-node from completing on heterogeneous hardware, which is intentional in the lab where we deliberately mix one md-capable drive and one md-less drive to exercise both alceml modes (method=1 on-device, method=2 fallback) in the same cluster. Fallback: when bdev_raid_create returns false, log a warning and proceed with a single-bdev JM on jm_nvme_bdevs[0]. The persisted JMDevice carries only that bdev in jm_nvme_bdev_list, so the restart path naturally takes its existing len==1 branch (recreate from single bdev, no RAID). Same behavior in both call paths -- the "jm_device.raid_bdev already set" branch (post-restart recreate) and the fresh-create branch. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Replace the AWS variant's "fio runs continuously across outages plus a
3-20 minute background churn timer" pattern with a deterministic
per-iteration cycle:
1. start fio on every volume
2. apply the dual-node outage pair (fio takes the hit)
3. wait for both nodes back online + post-outage check_fio (fault gate)
4. stop fio
5. optionally rebuild one randomly-selected volume
(every --churn-every-n-iters iterations; default 3)
6. wait_for_cluster_stable + wait_for_data_migration_complete --
UNLOADED, so migration drains fast
Why: the previous variant kept fio running across the rebalance/data-
migration drain, which dragged out iteration time massively under IO
pressure. New pattern keeps the "fio survives outage" coverage but
runs settling unloaded, so iteration time tracks the bare-cluster
rebalance time. Trades "outage + concurrent volume churn" coverage
(churn timer used to overlap outages occasionally) for predictable
per-iteration timing.
What's gone:
- background churn thread + serial_lock + churn_stop_event +
churn_error + reraise_churn_error + start/stop_churn_thread
- --churn-min-seconds / --churn-max-seconds (replaced by
--churn-every-n-iters; --no-churn still works)
- inter-iteration NIC chaos and its --nic-chaos-duration /
--no-nic-chaos / _ensure_all_data_nics_up / _disable_nic_on_all_nodes
/ _enable_nic_on_all_nodes helpers
- per-job fio teardown helpers (_check_one_fio, _stop_fio_for_job):
churn no longer touches fio because fio is already stopped when
churn fires
What's kept:
- all outage methods (graceful/forced/container_kill/host_reboot/
network_outage_*)
- method-pair x role-category enumeration, shuffling, --start-at,
--cycles
- check_fio fault contract (rc_file / wrapper-gone / stderr error
are all faults)
- lvol-disconnect/unmount/delete/recreate/connect/mkfs/mount cycle
(just driven serially from the main loop now)
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Control plane was still pulling simplyblock:main, which lacks the inline-checksum NVMeDevice model fields. Tag the branch build to match the ultra:checksum-validation-latest data-plane image so deploys from this branch get a self-consistent control plane. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
CI tags by branch name (workflow at .github/workflows/docker-image.yml runs sed 's|/|-|g' on the ref). The image is pushed as simplyblock:inline-checksum-validation, not :checksum-validation-latest (that suffix only applies to the ultra data-plane image). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
…eader, and stop suspend demote-after-block race cluster_activate Pass 2: on re-activation (suspended/active/degraded -> in_activation) the primary's LVS is still alive and serving I/O. The non-leader's bdev_examine of its raid0 then races the leader's blob- metadata writes and fails repeatedly with bs_load_cur_extent_page_valid "Extent page crc mismmatch" (observed 2026-05-11, LVS_6769 on node 8084 - examine loop ran 22+ min). Wrap recreate_lvstore_on_non_leader with a firewall-only port-block on the live leader for re-activation only; first-time activation keeps the existing activation_mode=True path unchanged. Port-block is benign on peers without fully-built stacks, so no per-node "fully recovered" tracking is needed; peer LVS / hublvol / distrib RPCs stay disabled by activation_mode. suspend_storage_node: drop the explicit bdev_lvol_set_leader(False) + bdev_distrib_force_to_non_leader that ran after blocking lvs+hublvol ports. With both ports already blocked the surviving peer auto-promotes; the explicit demote then races pre-block in-flight IO still being processed on the local distrib (port block doesn't halt internal distrib processing of already-queued requests) and completes it as non-leader -> writer conflict. Regression tests cover: re-activation port-block sequence, first-time activation does not port-block, finally-unblock on LVSRestartRequiredError, port_allow_task fallback on unblock RPC failure, and suspend no longer calls bdev_lvol_set_leader / bdev_distrib_force_to_non_leader for either own-primary or secondary/tertiary LVS. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
48245dc to
4748981
Compare
|
|
||
| def format_nvme_device(nvme_device: str, lbaf_id: int): | ||
| if is_namespace_4k_from_nvme_list(nvme_device): | ||
| def format_nvme_device(nvme_device: str, lbaf_id: int, force_reformat: bool = False): |
| if cached is not None: | ||
| try: | ||
| cached.close() | ||
| except Exception: |
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- cli-reference.yaml: add --enable-inline-checksum under storage-node configure, cluster create and cluster deploy. The flag was hand-edited into cli.py but missing from the YAML source-of-truth, so the generator kept dropping it. - storage_node_ops.py: annotate attached as set[str] for mypy. - test_subsystem_add_ns_idempotent.py: drop unused MagicMock import. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
…traint Commit 63bcef7 tightened HUBLVOL_FAST_IO_FAIL_TIMEOUT_SEC from 5 to 1 to collapse peer-death latency, but left HUBLVOL_RECONNECT_DELAY_SEC at 2. SPDK's bdev_nvme_check_io_error_resiliency_params requires reconnect_delay_sec <= fast_io_fail_timeout_sec, so every bdev_nvme_attach_controller for a hublvol fails locally before any network attempt with: bdev_nvme.c:6693:bdev_nvme_check_io_error_resiliency_params: *ERROR*: reconnect_delay_sec can't be more than fast_io_fail_timeout_sec. Observed on cluster a47ebe63: after activation completed, all six tertiary-role hublvol controllers stayed missing across all six nodes, the reconciler kept retrying every path and getting falsy back, and sn check failed. Basic IO still worked because primary path was unaffected, but every failover path (secondary->primary, tertiary->primary, tertiary->secondary) had no redirect controller. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
After a lab redeploy, cluster_metadata_base.json still references the previous deploy's cluster_uuid, per-node UUIDs and LVS names, so the soak scripts fail on the first sbctl cluster get <stale-uuid>. setup_lab_perf_test1.py only writes the metadata as part of a full deploy. This adds a minimal entry point that rewrites just the cluster-specific blocks (cluster_uuid, topology) in place and leaves the static lab topology (mgmt/storage_nodes/clients) untouched. Uses the same FDB-querying snippet as setup_lab_perf_test1.fetch_cluster_topology and the same sshpass+ssh transport, so prerequisites match. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
checksum-validation. Optional, frozen at cluster-create time, no upgrade path for existing clusters.Cluster.inline_checksum,NVMeDevice.md_size/md_supported,bdev_alceml_createchecksum-method kwargs, and per-cluster CLI flags oncluster create,cluster add, andsn configure.bdev_get_bdevsmd_sizefield (spdk_bdev_get_md_size), so a cluster can mix md-on-device and fallback drives. Capacity overhead from the fallback layout (6 / 510 blocks per 2 MiB extent ≈ 1.17%) is charged as initial provisioned utilization rather than reducing reported raw capacity.Why this branch and not main
aa81fafe(iteration-77 hang fix) on 2026-04-30. Those four hunks were removed in5ff3e214so main is clean again. This branch carries the full feature in one self-contained commit on top of that clean main.Design ref
Compatibility
False; existing clusters and code paths unchanged.md_sizedirectly from the bound bdev, so the control plane only flipschecksum_validation_method1/2/0 — matching thechecksum-validationbranch RPC schema (checksum_validation_method,cache_size,cache_eviction_threshold).Test plan
tests/test_inline_checksum.py(model defaults,find_md_lbaf_id,alceml_checksum_params, fallback-overhead math, RPC param wire-up for each method,addNvmeDevicesmd detection from a mocked bdev payload). All pass.--enable-inline-checksum, mixing one drive formatted with an md-capable LBAF (cv_md_method) and one without (cv_fallback_method); verify capacity reporting reflects the ~1.17% pre-charge only on the fallback drive.inline_checksumfield in DB) read back asFalseand behave exactly as today.Open follow-ups (not blocking this PR)
add_cluster/cluster addcontroller has a pre-existing positional-arg shift aroundfabric(unrelated to this work). New kwarg added keyword-only so it isn't affected; bug should be fixed separately.sb cluster get-capacity) is fed from Prometheus and reflects what alceml itself reports; the per-device pre-charge added here is in the lvol-create provisioning gate. If we want it visible incluster get-capacitytoo, that's a small extension to the stats collector.🤖 Generated with Claude Code