Not much more to say.

Also adds the IRQ handlers for the M0

schneider42 and others added 6 commits June 14, 2015 18:07
According to the LPC43xx User Manual (rev 2.1) a 0 in DAC_CR_BIAS bit leads to shorter settling times and higher power consumption.
Fix DAC (short) settling time bit handling