ib_info.sh

Collect InfiniBand hardware and configuration details from cluster nodes running RHEL 8 / Rocky Linux 8 with Mellanox ConnectX adapters. Outputs one CSV row per unique Mellanox card to stdout; errors and warnings are buffered in memory and flushed to stderr as a labeled block at exit. No files are written on the node.

Quick Start

Single node:

sudo ./ib_info.sh

Cluster-wide via clush:

clush -a 'sudo /shared/ib_tools/ib_info.sh' > cluster_ib.csv 2> cluster_ib_errors.log

Print the CSV header:

./ib_info.sh --header

CSV Output Format

"Hostname","Serial Number","Model","OS","Kernel","Mellanox Card Model","Driver Type","Installed OFED","Loaded OFED","Firmware Version"
  • One row per unique Mellanox card (dual-port cards produce one row, not two).
  • Fields fall back to UNAVAILABLE when a tool is missing or a command fails; the script continues collecting whatever it can rather than aborting.

Error Output Format (stderr)

=== IB_INFO ERRORS: node001 ===
[2026-02-21 19:18:47] node001 ERROR: No Mellanox cards found
[2026-02-21 19:18:47] node001 INFO:  Completed with 1 error(s), 0 warning(s)
=== END: node001 ===

When run via clush, each node's error block is tagged with the hostname so blocks from different nodes can be separated in the aggregated stderr stream.

Requirements

  • bash 5.x
  • lspci (pciutils) — required, detects Mellanox cards
  • ethtool — required, reads firmware version
  • dmidecode — optional, reads chassis serial and model
  • ofed_info — optional, reads installed OFED version
  • lsb_release or /etc/os-release — optional, reads OS version
  • Standard utilities: hostname, ip, awk, sed, grep, find, uname, rpm

Most commands must be run as root or with equivalent privileges.

Installation

  1. Copy the script to a shared path accessible from all cluster nodes (typically an NFS-mounted directory):

    chmod +x ib_info.sh
    sudo cp ib_info.sh /shared/ib_tools/
  2. Run directly on a single node or broadcast with clush:

    # Single node
    sudo /shared/ib_tools/ib_info.sh
    
    # All nodes — CSV to file, errors to separate file
    clush -a 'sudo /shared/ib_tools/ib_info.sh' > cluster_ib.csv 2> cluster_ib_errors.log
    
    # Specific nodes
    clush -w node[001-010] 'sudo /shared/ib_tools/ib_info.sh' > cluster_ib.csv 2> cluster_ib_errors.log

Exit Codes

Code Meaning
0 Success (or warnings only)
1 One or more errors logged (e.g., no Mellanox cards found)

When broadcast via clush, the overall exit code is non-zero if any node returned 1.

Troubleshooting

  • Permission errors: run with sudo or as root — dmidecode, ethtool, and lspci require elevated privileges.
  • Missing commands: install the missing packages (pciutils, ethtool, dmidecode). The script logs which tools are missing and continues with UNAVAILABLE for affected fields.
  • No Mellanox devices found: verify the host has Mellanox adapters and that at least one IB link is up (ip link).
  • OFED version mismatch warning: the installed OFED version differs from the loaded kernel module version — a reboot or systemctl restart openibd is likely needed.

License

No license is provided in this repository. If you intend to share or publish this script, please add a LICENSE file (e.g., MIT or Apache 2.0) to make redistribution terms explicit.

Contact

If you need help adapting the script to your environment, open an issue or contact the repository owner.

About

No description, website, or topics provided.

Resources

Stars

Watchers

Forks

Releases

No releases published

Packages

 
 
 

Contributors

Languages