Notifications
You must be signed in to change notification settings - Fork 96
Open
Description
Hello,
we have a FAS8200 and after a reboot the uptime check give following message.
**ePN /usr/local/icinga/libexec//check_netapp_ng.pl: plugin did not call exit()
The reason ist for the first day after a reboot the uptime output from snmp is
4 hours, 44:54.86
The check expected something like 4 days, 7:14:35:17.12
I have no experience with github so i do not know how i upload the fixed code.
Here my recommended code.
### UPTIME ###
} elsif("$opt{'check_type'}" eq "UPTIME") {
my $check = _get_oid_value($snmp_session,$snmpUpTime);
$msg = "$opt{'check_type'}: $check";
if ($check =~ /hours/){
$check =~ m/^\s*(\d+)\s+hours,\s+(\d+):(\d+).*$/;
$perf = "uptime=" . ($1*3600 + $2*60 + $3) . "s";
}else{
$check =~ m/^\s*(\d+)\s+days,\s+(\d+):(\d+):(\d+).*$/;
$perf = "uptime=" . ($1*86400 + $2*3600 + $3*60 + $4) . "s";
}
Metadata
Metadata
Assignees
Labels
No labels