You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
@@ -3935,30 +3917,6 @@ <h2 id="which-devices-are-compatible">Which Devices Are Compatible?<a class="hea
3935
3917
<p>The developers maintain support for the current and one-level earlier <em><abbrtitle="operating system used by Apple Mobile devices (iPhone, iPod, iPad)">iOS</abbr></em></p>
3936
3918
</li>
3937
3919
</ul>
3938
-
<h3id="iphone-16-and-inplay-dash-pods">iPhone 16 and InPlay DASH pods<aclass="headerlink" href="#iphone-16-and-inplay-dash-pods" title="Anchor link to this Header on this Page">¶</a></h3>
3939
-
<divclass="admonition warning">
3940
-
<pclass="admonition-title">iPhone 16 and <abbrtitle="Insulet tubeless insulin pump; Loop supports Eros (with RileyLink) and DASH. Eros is also known as Classic, UST400, and System.">Omnipod</abbr> DASH</p>
3941
-
<p>Some of the DASH pods produced in 2025 have different chips and firmware. </p>
3942
-
<ul>
3943
-
<li>These pods, which advertise a Bluetooth Device name of <code>InPlay BLE</code> and indicate <code>-Atlas</code> in small print on the paper pod cover are fully compatible with all iPhone models except iPhone 16</li>
3944
-
<li>Early reports indicate the <code>InPlay BLE</code> pods work fine with iPhone 17</li>
3945
-
<li>Although <code>InPlay</code> pods do work with the 16 you may notice some communication issues<ul>
3946
-
<li>It can take many attempts to get the pod to initially connect when pairing; just keep hitting retry</li>
3947
-
<li>Once the pod disconnects itself from the phone Bluetooth, the phone is slow to reconnect the pod to the <em><abbrtitle="With a capital L, Loop is one of several do-it-yourself artifical pancreas systems">Loop</abbr></em> app<ul>
3948
-
<li>Pod firmware initiates the disconnect 3 minutes after the last message exchange</li>
3949
-
<li>With other models, the reconnect happens in about 1 sec</li>
3950
-
<li>With iPhone 16, this can take many seconds and sometimes a few minutes</li>
3951
-
</ul>
3952
-
</li>
3953
-
<li>When the pod is not connected, neither automatic nor manual commands can be sent to the pod to modify insulin delivery</li>
3954
-
<li>No solution to this issue is known</li>
3955
-
</ul>
3956
-
</li>
3957
-
</ul>
3958
-
<blockquote>
3959
-
<p>DASH pods that advertise a Bluetooth Device name of <code>TWI Board</code> and indicate <code>-SAW</code> in small print on the paper pod cover are fully compatible with all phones included the iPhone 16.</p>
3960
-
</blockquote>
3961
-
</div>
3962
3920
<h3id="compatible-device">Compatible Device<aclass="headerlink" href="#compatible-device" title="Anchor link to this Header on this Page">¶</a></h3>
3963
3921
<p>All the devices listed below are currently compatible with <abbrtitle="With a capital L, Loop is one of several do-it-yourself artifical pancreas systems">Loop</abbr>. They are separated by the available <em><abbrtitle="operating system used by Apple Mobile devices (iPhone, iPod, iPad)">iOS</abbr></em> for the phone. </p>
3964
3922
<p>These phones require <em><abbrtitle="operating system used by Apple Mobile devices (iPhone, iPod, iPad)">iOS</abbr></em> 26 and <code>Loop version 3.8.x</code> or newer</p>
<p>These phones require <em><abbrtitle="operating system used by Apple Mobile devices (iPhone, iPod, iPad)">iOS</abbr></em> 18 and are compatible with <em><abbrtitle="operating system used by Apple Mobile devices (iPhone, iPod, iPad)">iOS</abbr></em> 26</p>
3969
3927
<ul>
3970
-
<li>iPhone 16, all variants</li>
3928
+
<li>iPhone 16, all variants (phone is compatible but see <ahref="../../faqs/omnipod-faqs/#iphone-16-and-atlas-or-inplay-dash-pods" target="_blank">InPlay DASH pod</a> warning)</li>
3971
3929
</ul>
3972
3930
<p>These phones are compatible with <em><abbrtitle="operating system used by Apple Mobile devices (iPhone, iPod, iPad)">iOS</abbr></em> 17, 18 and 26</p>
<li>If you have a Medtronic pump, check the <ahref="#check-medtronic-pump-version">Medtronic Pump Version</a> list to ensure compatible model/firmware</li>
4015
4015
<li>If you use <ahref="#omnipod-pumps"><abbrtitle="Insulet tubeless insulin pump; Loop supports Eros (with RileyLink) and DASH. Eros is also known as Classic, UST400, and System.">Omnipod</abbr></a> - check which kind</li>
4016
4016
<li>If you use <ahref="#sooil-dana-pumps">Dana</a> - check which kind</li>
4017
-
<li>If you use <ahref="#medtrum-touchcare-nano">Medtrum Nano</a> - Check which loop version</li>
4017
+
<li>If you use <ahref="#medtrum-nano">Medtrum Nano</a> - Check which loop version</li>
4018
4018
</ul>
4019
4019
</div>
4020
4020
<divclass="admonition question">
@@ -4239,7 +4239,9 @@ <h3 id="danars">DanaRS<a class="headerlink" href="#danars" title="Anchor link to
4239
4239
<h2id="medtrum-nano">Medtrum Nano<aclass="headerlink" href="#medtrum-nano" title="Anchor link to this Header on this Page">¶</a></h2>
4240
4240
<divclass="admonition warning">
4241
4241
<pclass="admonition-title">You must build feat/dev-medtrum <abbrtitle="version of code within a single repository or workspace repository">branch</abbr> to use Medtrum patch pumps</p>
4242
-
<p>The Medtrum patch pump is in feat/dev-medtrum (as of version v3.9.0) and is experimental as of now</p>
4242
+
<p>The Medtrum patch pump is in feat/dev-medtrum (as of version v3.9.0) and is experimental as of now.</p>
4243
+
<p><strong>Be very careful running this. The initial version had a bug where a delivered bolus was not always recorded properly. This is just one example of why only experts should volunteer to test experimental code.</strong></p>
4244
+
<p>Follow along in the <ahref="https://loop.zulipchat.com/#narrow/channel/144182-development/topic/Medtrum.20Nano.20-.20pumps.20for.20development.20use/with/481836247">zulipchat Medtrum channel</a>.</p>
4243
4245
</div>
4244
4246
<divclass="admonition info">
4245
4247
<pclass="admonition-title">All versions are supported!</p>
Copy file name to clipboardExpand all lines: build/rileylink/index.html
+2-6Lines changed: 2 additions & 6 deletions
Original file line number
Diff line number
Diff line change
@@ -3729,16 +3729,12 @@
3729
3729
<h1>RileyLink</h1>
3730
3730
3731
3731
<h2id="order-a-rileylink-compatible-device">Order a <abbrtitle="radio-frequency device Loop uses to control Eros pods (aka. Gen 3) and older Medtronic pumps">RileyLink</abbr> Compatible Device<aclass="headerlink" href="#order-a-rileylink-compatible-device" title="Anchor link to this Header on this Page">¶</a></h2>
3732
-
<p><strong>Not needed for any pump that supports direct Bluetooth <abbrtitle="Bluetooth low energy, used for communication by phones, CGM and some pumps">BLE</abbr> commands</strong></p>
3733
-
<ul>
3734
-
<li><strong>Dana</strong></li>
3735
-
<li><strong>DASH</strong></li>
3736
-
</ul>
3732
+
<p><strong>Not needed for any pump that supports direct Bluetooth <abbrtitle="Bluetooth low energy, used for communication by phones, CGM and some pumps">BLE</abbr> commands such as Dana, DASH and Medtrum</strong></p>
3737
3733
<p><strong>Required when using an older Medtronic pump or <abbrtitle="Insulet tubeless insulin pump; Loop supports Eros (with RileyLink) and DASH. Eros is also known as Classic, UST400, and System.">Omnipod</abbr> Eros pods</strong></p>
3738
3734
<divclass="admonition info">
3739
3735
<pclass="admonition-title">Time Estimate</p>
3740
3736
<ul>
3741
-
<li>0 minutes if you plan to use a Dana pump or a DASH<abbrtitle="Insulet tubeless insulin pump; Loop supports Eros (with RileyLink) and DASH. Eros is also known as Classic, UST400, and System.">Omnipod</abbr>pump - you don't need one</li>
3737
+
<li>0 minutes if you plan to use a pump that supports direct<abbrtitle="Bluetooth low energy, used for communication by phones, CGM and some pumps">BLE</abbr>communication - you don't need one</li>
3742
3738
<li>15-20 minutes to read about <abbrtitle="radio-frequency device Loop uses to control Eros pods (aka. Gen 3) and older Medtronic pumps">RileyLink</abbr> compatible devices</li>
0 commit comments